VoltiE DC Fast RT175-S
175 kW CCS / CHAdeMO
- Up to 175 kW DC output from 200 V to 920 V
- Single CCS or dual CCS and CHAdeMO connector options
- Outdoor rated enclosure, IP65 (NEMA 3R) with IK10 impact protection
Overview
The VoltiE RT175-S is a high power DC fast charger delivering up to 175 kW of output for corridor, fleet, and public charging sites. Hardware and enclosure are based on the proven RT175-S platform, now integrated into VoltiE services, support, and CSMS.
Configurable variants support single or dual DC outlets so that sites can deploy CCS only or CCS and CHAdeMO combinations. Power is dynamically shared by the charger control system according to connector usage and configuration policies.
The cabinet is designed for challenging outdoor environments with an IP65 (NEMA 3R) weather rating and IK10 impact protection with IK8 screen. High efficiency operation minimizes energy losses while maintaining stable performance at high currents.
Integration with the VoltiE CSMS uses standard OCPP communications, enabling central monitoring, remote diagnostics, and access control policies for public, fleet, and site specific use cases.
Technical Specifications
⚡ Electrical
- Charging level
- DC fast charging
- Maximum output power
- Up to 175 kW DC (site and configuration dependent)
- Output voltage
- 200 V to 920 V DC
- Output current
- CCS up to 350 A; CHAdeMO up to 200 A
- Connectors
- Single: CCS; Dual: CCS and CHAdeMO (connector types vary by region)
- Connector types
-
Worldwide: CCS2 or CCS2 and CHAdeMOUS and Canada: CCS1 or CCS1 and CHAdeMO
- Efficiency
- 98.5 percent at full load (350 A, 500 V)
🧰 Mechanical and environment
- IP rating / IK rating
- IP65 (NEMA 3R); IK10 with IK8 screen
- Operating temperature
- -30 °C to 50 °C (-22 °F to 122 °F)
- Storage temperature
- -55 °C to 80 °C (-67 °F to 176 °F)
- Dimensions (H x W x D)
- 2,011 mm (6 ft 7 in) x 993 mm (3 ft 3 in) x 531 mm (1 ft 9 in) – width excludes plugs
- Weight
- 277 kg (611 lb)
- Cable reach
- 4.1 m (13 ft 5 in)
- Cable management
- Fitted standard
💳 Authentication and compliance
- Card reader / RFID
- Card reader optional; RFID support available
- Authentication / payment
- RFID only or credit card reader with RFID, depending on configuration
- Compliance
- UL NRTL certification; FCC Class A
Installation
- Requires dedicated commercial service and three phase distribution designed for the site; utility coordination is recommended for new installations.
- Confirm panel capacity, feeder sizing, fault current ratings, and grounding according to local electrical codes and engineering guidelines.
- Provide clear approach space for vehicles, with adequate bollards and mounting pad according to manufacturer foundation drawings.
Isolated Power Unit (IPU)
⚡ Electrical and isolation
- Input voltage
-
Worldwide (400 VAC): 400 VAC 3-phase ±10 %, 50 Hz ±10 %, derate power below −10 % to −15 %, 270 A nominal, 300 A maximum (at low line)US and Canada (480 VAC): 480 VAC 3-phase ±10 %, 60 Hz ±10 %, derate power below −10 % to −15 %, 225 A nominal, 250 A maximum (at low line)Canada (600 VAC): 600 VAC 3-phase ±10 %, 60 Hz ±10 %, derate power below −10 % to −15 %, 180 A nominal, 200 A maximum (at low line)
- Input overvoltage category
- Category III
- Output voltage / power
- 950 V DC, up to 178 kW
- Isolation
- Reinforced isolating transformer with double / reinforced insulation between AC mains and EV side
- Efficiency
- 96 percent at full load
- Power factor
- > 0.99
- Total harmonic distortion
- < 5 percent
🌡 Environment and enclosure
- Operating temperature
-
-10 °C to 50 °C (14 °F to 122 °F), 5–95 percent RH non condensing (without optional cold kit)-30 °C to 50 °C (-22 °F to 122 °F), 5–95 percent RH non condensing (with optional cold kit)
- Storage temperature
- -55 °C to 80 °C (-67 °F to 176 °F), 5–95 percent RH non condensing
- Network connection
- Ethernet link from power unit to user unit
- Dimensions (H x W x D)
- 2,110 mm (6 ft 11 in) x 660 mm (2 ft 2 in) x 1,060 mm (3 ft 6 in)
- Weight
- 1004 kg (2213.5 lb)
- IK rating
- IK10
- IP rating
- IP55 (NEMA 3R)
📡 Communications and control
- Wireless uplink
- 3G / 4G cellular communications with failover redundancy
- Wired uplink
- Ethernet
- Power supply
- Battery backed UPS functionality for reliable telemetry at all times
- Software support
- OCPP v1.6J support for management and billing
- Security
- SSH with EC keys and unique password for manufacturer diagnostics
- Power control
- Supports OCPP charging profiles (OCPP v1.6J)
- Control platform
- Included within the power unit
- Power sharing (optional)
- Configurable site level power demand management
📘 EMC
- Worldwide
- EMC Directive, immunity Class A, emissions Class A
- USA
- FCC, immunity Class A, emissions Class A
AC Grid Interface
🔌 AC supply and protection
- Voltage
-
Worldwide (400 VAC): 400 VAC 3-phase ±10 %US and Canada (480 VAC): 480 VAC 3-phase ±10 %Canada (600 VAC): 600 VAC 3-phase ±10 %Frequency: Worldwide 50 Hz ±10 %, US and Canada 60 Hz ±10 %
- Maximum current at low line
-
Worldwide (400 VAC): 300 AUS and Canada (480 VAC): 250 ACanada (600 VAC): 200 AValues at nominal voltage −10 % and PF = 0.99
- Over current protection
-
Worldwide (400 VAC): 300 A UL listed circuit breaker recommended; rating must not exceed 300 A to protect the LV transformer in the IPU (larger breakers require increased cable gauge).US and Canada (480 VAC): 320 A UL listed circuit breaker recommended; rating must not exceed 320 A.Canada (600 VAC): 250 A UL listed circuit breaker recommended; rating must not exceed 250 A.Current limiting fuses or a UL recognized current limiting breaker must be installed if available fault current exceeds 18 kA. The IPU has an option to upgrade the SCCR to 100 kA.
- Fault current limiting fuses
- Provided in the site distribution board as required by local codes and fault current levels.
- Residual current monitoring
- If required by local regulation, the residual current monitoring device shall be of time delay type.
- Under voltage relay
- Optional under voltage relay coil on the feeder circuit breaker can be used to isolate the IPU upstream during safety loop events.
🛡 Safety and installation guidance
- Isolation behaviour
- The isolated power unit includes circuitry to locally isolate the charger power circuit if the safety loop monitoring the door switches and tilt sensors is triggered.
- Electrical installation
- Systems must be installed by a licensed contractor and licensed electrician in accordance with all applicable local and national codes and standards, including NEC and NFPA 70E requirements. Additional lockable disconnect mechanisms may be required within line of sight of the supplied equipment.
📏 Cable sizing for AC link
- Minimum buried cable size
-
Length of AC link cables and system efficiency should be considered when sizing cables.Worldwide (400 VAC): Twin 70 mm² Cu for L1, L2, L3; single 70 mm² Cu for PEUS and Canada (480 VAC): Twin 3/0 Cu for L1, L2, L3; single 3/0 Cu for PECanada (600 VAC): Twin 1/0 Cu for L1, L2, L3; single 1/0 Cu for PE
- Maximum buried cable length
- 200 m (656 ft) for the minimum AC link cable sizes specified, to maintain feeder voltage drop below 3 percent.
VoltiE DC Fast RT175-S
175 kW CCS / CHAdeMO
- Up to 175 kW DC output from 200 V to 920 V
- Single CCS or dual CCS and CHAdeMO connector options
- Outdoor rated enclosure, IP65 (NEMA 3R) with IK10 impact protection
Overview
The VoltiE RT175-S is a high power DC fast charger delivering up to 175 kW of output for corridor, fleet, and public charging sites. Hardware and enclosure are based on the proven RT175-S platform, now integrated into VoltiE services, support, and CSMS.
Configurable variants support single or dual DC outlets so that sites can deploy CCS only or CCS and CHAdeMO combinations. Power is dynamically shared by the charger control system according to connector usage and configuration policies.
The cabinet is designed for challenging outdoor environments with an IP65 (NEMA 3R) weather rating and IK10 impact protection with IK8 screen. High efficiency operation minimizes energy losses while maintaining stable performance at high currents.
Integration with the VoltiE CSMS uses standard OCPP communications, enabling central monitoring, remote diagnostics, and access control policies for public, fleet, and site specific use cases.
Technical Specifications
⚡ Electrical
- Charging level
- DC fast charging
- Maximum output power
- Up to 175 kW DC (site and configuration dependent)
- Output voltage
- 200 V to 920 V DC
- Output current
- CCS up to 350 A; CHAdeMO up to 200 A
- Connectors
- Single: CCS; Dual: CCS and CHAdeMO (connector types vary by region)
- Connector types
-
Worldwide: CCS2 or CCS2 and CHAdeMOUS and Canada: CCS1 or CCS1 and CHAdeMO
- Efficiency
- 98.5 percent at full load (350 A, 500 V)
🧰 Mechanical and environment
- IP rating / IK rating
- IP65 (NEMA 3R); IK10 with IK8 screen
- Operating temperature
- -30 °C to 50 °C (-22 °F to 122 °F)
- Storage temperature
- -55 °C to 80 °C (-67 °F to 176 °F)
- Dimensions (H x W x D)
- 2,011 mm (6 ft 7 in) x 993 mm (3 ft 3 in) x 531 mm (1 ft 9 in) – width excludes plugs
- Weight
- 277 kg (611 lb)
- Cable reach
- 4.1 m (13 ft 5 in)
- Cable management
- Fitted standard
💳 Authentication and compliance
- Card reader / RFID
- Card reader optional; RFID support available
- Authentication / payment
- RFID only or credit card reader with RFID, depending on configuration
- Compliance
- UL NRTL certification; FCC Class A
Installation
- Requires dedicated commercial service and three phase distribution designed for the site; utility coordination is recommended for new installations.
- Confirm panel capacity, feeder sizing, fault current ratings, and grounding according to local electrical codes and engineering guidelines.
- Provide clear approach space for vehicles, with adequate bollards and mounting pad according to manufacturer foundation drawings.
Isolated Power Unit (IPU)
⚡ Electrical and isolation
- Input voltage
-
Worldwide (400 VAC): 400 VAC 3-phase ±10 %, 50 Hz ±10 %, derate power below −10 % to −15 %, 270 A nominal, 300 A maximum (at low line)US and Canada (480 VAC): 480 VAC 3-phase ±10 %, 60 Hz ±10 %, derate power below −10 % to −15 %, 225 A nominal, 250 A maximum (at low line)Canada (600 VAC): 600 VAC 3-phase ±10 %, 60 Hz ±10 %, derate power below −10 % to −15 %, 180 A nominal, 200 A maximum (at low line)
- Input overvoltage category
- Category III
- Output voltage / power
- 950 V DC, up to 178 kW
- Isolation
- Reinforced isolating transformer with double / reinforced insulation between AC mains and EV side
- Efficiency
- 96 percent at full load
- Power factor
- > 0.99
- Total harmonic distortion
- < 5 percent
🌡 Environment and enclosure
- Operating temperature
-
-10 °C to 50 °C (14 °F to 122 °F), 5–95 percent RH non condensing (without optional cold kit)-30 °C to 50 °C (-22 °F to 122 °F), 5–95 percent RH non condensing (with optional cold kit)
- Storage temperature
- -55 °C to 80 °C (-67 °F to 176 °F), 5–95 percent RH non condensing
- Network connection
- Ethernet link from power unit to user unit
- Dimensions (H x W x D)
- 2,110 mm (6 ft 11 in) x 660 mm (2 ft 2 in) x 1,060 mm (3 ft 6 in)
- Weight
- 1004 kg (2213.5 lb)
- IK rating
- IK10
- IP rating
- IP55 (NEMA 3R)
📡 Communications and control
- Wireless uplink
- 3G / 4G cellular communications with failover redundancy
- Wired uplink
- Ethernet
- Power supply
- Battery backed UPS functionality for reliable telemetry at all times
- Software support
- OCPP v1.6J support for management and billing
- Security
- SSH with EC keys and unique password for manufacturer diagnostics
- Power control
- Supports OCPP charging profiles (OCPP v1.6J)
- Control platform
- Included within the power unit
- Power sharing (optional)
- Configurable site level power demand management
📘 EMC
- Worldwide
- EMC Directive, immunity Class A, emissions Class A
- USA
- FCC, immunity Class A, emissions Class A
AC Grid Interface
🔌 AC supply and protection
- Voltage
-
Worldwide (400 VAC): 400 VAC 3-phase ±10 %US and Canada (480 VAC): 480 VAC 3-phase ±10 %Canada (600 VAC): 600 VAC 3-phase ±10 %Frequency: Worldwide 50 Hz ±10 %, US and Canada 60 Hz ±10 %
- Maximum current at low line
-
Worldwide (400 VAC): 300 AUS and Canada (480 VAC): 250 ACanada (600 VAC): 200 AValues at nominal voltage −10 % and PF = 0.99
- Over current protection
-
Worldwide (400 VAC): 300 A UL listed circuit breaker recommended; rating must not exceed 300 A to protect the LV transformer in the IPU (larger breakers require increased cable gauge).US and Canada (480 VAC): 320 A UL listed circuit breaker recommended; rating must not exceed 320 A.Canada (600 VAC): 250 A UL listed circuit breaker recommended; rating must not exceed 250 A.Current limiting fuses or a UL recognized current limiting breaker must be installed if available fault current exceeds 18 kA. The IPU has an option to upgrade the SCCR to 100 kA.
- Fault current limiting fuses
- Provided in the site distribution board as required by local codes and fault current levels.
- Residual current monitoring
- If required by local regulation, the residual current monitoring device shall be of time delay type.
- Under voltage relay
- Optional under voltage relay coil on the feeder circuit breaker can be used to isolate the IPU upstream during safety loop events.
🛡 Safety and installation guidance
- Isolation behaviour
- The isolated power unit includes circuitry to locally isolate the charger power circuit if the safety loop monitoring the door switches and tilt sensors is triggered.
- Electrical installation
- Systems must be installed by a licensed contractor and licensed electrician in accordance with all applicable local and national codes and standards, including NEC and NFPA 70E requirements. Additional lockable disconnect mechanisms may be required within line of sight of the supplied equipment.
📏 Cable sizing for AC link
- Minimum buried cable size
-
Length of AC link cables and system efficiency should be considered when sizing cables.Worldwide (400 VAC): Twin 70 mm² Cu for L1, L2, L3; single 70 mm² Cu for PEUS and Canada (480 VAC): Twin 3/0 Cu for L1, L2, L3; single 3/0 Cu for PECanada (600 VAC): Twin 1/0 Cu for L1, L2, L3; single 1/0 Cu for PE
- Maximum buried cable length
- 200 m (656 ft) for the minimum AC link cable sizes specified, to maintain feeder voltage drop below 3 percent.